8 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
Dimensions: 7.8(d) x 4.8(w) x 1.6(h) in. (19.81 x 12.19 x 4.06 cm) (1U height)
Weight: 1.5 lb. (0.68 kg), Fully loaded
32 KB per port
Mounts in a standard 19 in. rack with optional four-way mounting kit
Switching capacity: 1.6 Gbps
Routing table size: 1,000 entries
Operating temperature: 32ºF to 104ºF (0ºC to 40ºC)
Operating relative humidity: 15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature: -40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity: 15% to 90% @ 149ºF (65ºC), non-condensing
Shock and vibration: EN 60068 (IEC 68)
Altitude: up to 10,000 ft. (3 km)
Maximum heat dissipation: 52 BTU/hr (55 kJ/hr)
Voltage: 100-127 / 200-240 VAC
Current: 0.4 / 0.2 A
Power consumption: 15 W
Frequency: 50 / 60 Hz
Notes: Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
CSA 950; EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Generic: EN 55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3 V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3 V
Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN 61000-3-2, IEC 61000-3-2
Flicker: EN 61000-3-3, IEC 61000-3-3
General protocol |  | IEEE 802.3x Flow Control |